Skip to content
Draft — content may change

Trumouse Lite: Power Supply and Electrical Specifications

Table: External power inputs

Component Input Connector Power source
Reader Array (RFID floor platform) DC 5 V DC connector, 2 per block External low-ripple DC supply
Top Panel (White Light, Infrared Light, environmental sensor, Light Control Module and Exhaust Fan) DC 24 V DC connector External DC supply
Industrial Camera External 12 V / 24 V DC supply, or powered together with the Top Panel lighting 6-pin P7 connector External DC supply
Switch As specified by its manufacturer Mains plug Independent power supply
Compute Unit As specified by its manufacturer Mains plug Independent power supply

The Reader Array must be powered from a low-ripple DC supply. All external power supplies and the switch are certified commercial products. See Figure “Trumouse Lite interface locations (viewed from the right front)” for the location of the power connectors.

The Reader Array (RFID floor platform) is powered at 5 V DC. The Top Panel (White Light, Infrared Light, environmental sensor, Light Control Module and Exhaust Fan) is powered at 24 V DC. Industrial Camera power supply: External 12 V / 24 V DC supply, or powered together with the Top Panel lighting. The Compute Unit has its own power supply. All DC supplies in the system are 24 V or lower.

Table: Estimated power consumption

Subsystem Power supply Estimated power (W)
Reader Array (RFID floor platform) 5 V DC 25
Infrared Lights 24 V DC 24
White Light 24 V DC 10
Industrial Camera 12 V or 24 V DC 1.8
Environmental Sensor 24 V DC 3
Total (excluding the Compute Unit) 63.8

The power figures are estimates and exclude the Compute Unit. The Industrial Camera uses the typical power consumption from its datasheet; the other figures are approximate.